QUESTION 136
Which three troubleshooting actions should an administrator take to address slow performance when deploying a virtual machine template? (Choose three.)

A.    Increase network throughput by adding additional uplinks to the vSwitch.
B.    Change the destination datastore or volume for the virtual machine template.
C.    Configure a Provisioning Traffic vmkernel port to perform the deployment operation.
D.    Reduce the size of the virtual machine template’s virtual disk.
E.    Deploy the virtual machine template to the cluster and allow Distributed Resource Scheduler to register the virtual machine.

Answer: ABC

QUESTION 137
When attempting to remove a host from a vSphere Distributed Switch (vDS), an administrator observes the error message:
The resource ’16’ is in use
What are two reasons why this error would be displayed? (Choose two.)

A.    VMkernel network adapters on the vDS are in use.
B.    Virtual machine network adapters are connected to the vDS.
C.    Network I/O Control has been configured on the vDS.
D.    There is active network traffic on the vDS.

Answer: AB

QUESTION 138
An administrator suspects that the MTU value for a vSphere Standard Switch is misconfigured. Which two commands can determine the value? (Choose two.)

A.    esxcfg-vswitch -l
B.    esxcli network vswitch standard list
C.    esxcfg-vss -l
D.    esxcli network standard vswitch list

Answer: AB

QUESTION 139
Deletion of an NFS datastore generates the following error:
Sysinfo error on operation returned the following status: Busy
Which step can be performed that will allow the deletion to complete successfully?

A.    Storage vMotion any virtual machines on the datastore to another location.
B.    Remove the datastore from the Storage DRS cluster in which it resides.
C.    Verify the value of the NFS.HeartbeatDelta is not set to 0.
D.    Suspend any running virtual machines and unmount the NFS datstore.

Answer: A

QUESTION 140
An administrator uses the df -h command and notices that an NFS datastore is reporting a capacity of 0 Bytes. What condition would cause this to occur?

A.    The NFS server on which the datastore resides is down.
B.    The datastore was mounted as Read/Write.
C.    The datastore was mounted as Read-Only.
D.    The datastore was created with NFS version 4.1.

Answer: A

QUESTION 141
The command esxcli network vm list displays four virtual machines connected to the Production vSwitch. Within the vSphere Web Client, five virtual machines are seen. What explains this behavior?

A.    The fifth virtual machine is currently powered off.
B.    The fifth virtual machine has two vnics.
C.    The fifth virtual machine has an invalid IP address.
D.    The fifth virtual machine has an invalid MAC address.

Answer: A

QUESTION 142
An administrator is experiencing network connectivity issues between virtual machines. The virtual machines and hosts are configured as follows:
– VM1 is running on Host1
– VM2 is running on Host2
– Both Host1 and Host2 are attached to the vSphere Distributed Switch dvSwitch1
– Both Host1 and Host2 are using vmnic0 and vmnic1 on dvSwitch1
– Both virtual machines are using the default portgroup for network traffic
What are three settings the administrator should investigate while troubleshooting the connectivity issue? (Choose three.)

A.    VLANs of the physical NICs
B.    Failover order of the uplinks
C.    Virtual NIC connectivity to the dvSwitch
D.    Security policy of the portgroup
E.    Traffic shaping on the portgroup

Answer: ABC

QUESTION 143
A task fails while creating a VMFS5 datastore on a disk with these characteristics:
– Was previously used by a Linux server
– Was not erased
– Is visible with the vSphere Web Client
Which action can be performed to resolve the issue?

A.    Delete the partitions on the disk manually with partedUtil first.
B.    Create a VMFS3 file system first, then upgrade it.
C.    Create the VMFS5 file system manually using vmkfstools.
D.    Delete the data with the vmkfstools command.

Answer: A

QUESTION 144
A vSphere Web Client task fails while creating a VMFS datastore on a disk with these characteristics:
– The disk was formatted with an Master Boot Record (MBR) partition table
– The disk was not erased
– The disk is visible in the vSphere Web Client
What action needs to be performed to resolve the issue?

A.    Delete the partitions manually with partedUtil.
B.    Create a VMFS3 file system first, then upgrade it.
C.    Create a VMFS5 file system with the command esxcli storage filesystem add.
D.    Delete the data with the vmkfstools command.

Answer: A

QUESTION 145
Which two reasons would prevent Storage Distributed Resource Scheduler (SDRS) from operating on a datastore? (Choose two.)

A.    The datastore has Storage I/O Control disabled.
B.    The datastore is connected to an unsupported host.
C.    The datastore is hosted on an NFS server.
D.    The datastore is hosted on an iSCSI server.

Answer: AB

QUESTION 146
What are two ways to view the DNS settings for an ESXi 6.x host? (Choose two.)

A.    Use the vicfg-dns command from the vSphere Management Appliance.
B.    View the /etc/resolv.conf file on the ESXi host.
C.    Use vicfg-dns command on the ESXi host.
D.    View the /etc/dns.conf file on the ESXi host.

Answer: AB

QUESTION 147
After configuring a Virtual SAN cluster, an administrator using the vSphere Web Client notices that the Virtual SAN datastore is smaller than expected. The cluster contains:
– Three ESXi hosts
– Each host has one 10GB SDD
– Each host has one 100GB HDD
Why would the Virtual SAN datastore show as 100GB instead of 300GB?

A.    There is a network problem with the Virtual SAN vmkernel ports.
B.    The Virtual SAN VASA provider is disabled.
C.    vSphere High Availability is enabled on the Virtual SAN cluster.
D.    The Virtual SAN cluster must be managed using the vSphere Web Client.

Answer: A

QUESTION 148
An administrator tries to capture network traffic for a virtual machine, but cannot see the expected traffic in the packet capture tool. Which step can resolve the problem?

A.    Migrate the virtual machine to a Distributed Virtual Switch.
B.    Enable Promiscous Mode on the relevant port group.
C.    Modify the default value of MAC Address changes.
D.    Enable Forged Transmits on the virtual machine.

Answer: B

QUESTION 149
An administrator creates a Private VLAN with a Primary VLAN ID of 2. The administrator than creates three Private VLANs as follows:
Marketing
PVLAN ID. 4
PVLAN Type. Isolated
Accounting
PVLAN ID. 5
PVLAN Type. Community
Secretary
PVLAN ID. 17
PVLAN Type. Isolated
Users in the Accounting PVLAN are reporting problems communicating with servers in the Marketing PVLAN. Which two actions could the administrator take to resolve this problem? (Choose two.)

A.    Change the PVLAN type for the Accounting network to Promiscuous.
B.    Change the PVLAN ID for the Accounting network to 2.
C.    Change the PVLAN type for Marketing network to Promiscuous.
D.    Change the PVLAN ID for Accounting network to 4.

Answer: AB

QUESTION 150
An administrator attempts to place a Storage DRS enabled Datastore into Maintenance Mode. The task never completes, and the Entering Maintenance Mode status remains at 1%. Which two actions should the administrator take to resolve this problem? (Choose two.)

A.    Set the Storage DRS advanced option IgnoreAffinityRulesForMaintenance = 1.
B.    Set the Storage DRS advanced option IgnoreAffinityRulesForMaintenance = 0.
C.    Disable Storage DRS affinity rules associated with this datastore cluster.
D.    Enable Storage DRS affinity rules associated with this datastore cluster.

Answer: AC


100% valid 2V0-621D exam questions from PassLeader 2V0-621D dumps! Welcome to download the newest & 100% pass guarantee PassLeader 2V0-621D VCE and PDF dumps: http://www.passleader.com/2v0-621d.html (256 Q&As)

P.S. Free & New 2V0-621D dumps are available on Google Drive shared by PassLeader: https://drive.google.com/open?id=0B-ob6L_QjGLpRDdvZTNjQUdZYUE